Static electricity generated during liquid flow of hazardous chemicals,It is a concealed fire source for tank filling operations.

■ Oil static eliminator
The oil static elimination device enhances the electric field potential between the induced charge and the liquid flow charge through the dielectric isolation layer, and realizes electrostatic neutralization by collecting the flow.


Technical Parameter
● Working pressure: ≤2.0MPa
● Outlet charge density: <30μC/m3
● Charge density monitoring error: ≤±0.1uC/m³
■ Electrostatic oil monitor

▲ Schematic diagram of charge density on-line monitoring
Application site
● Places where instantaneous flow rate will suddenly increase, such as centralized refueling equipment such as stack;
● The filter is too close to the tank truck or container, such as oil tankers, gas stations, aircraft and other filling places;
● Filling benzene, mixed benzene, crude benzene and other places;
● Places where the initial flow rate is too high, such as oil tanks, tank trucks and other equipment;
● Temporary refueling equipment or poorly grounded handling equipment;
● Handling of dirty oil, mixed oil, crude oil or workplaces containing more free water, etc.

▲ Measurement data of φ100 oil static elimination and monitoring system in static monitoring center